PT_logo_GV.jpg

Home | Company Profile | Products | Services | Pearl Farm Investment | Pearl Sales & Marketing | Equipment Trader | Contact Us | Gallery
Xray Machine Specifications

This system has been specifically designed to X-Ray seeded oysters. 

The features included in this machine have evolved by close liaison with the Pearling Industry over a period of many years.

  • Constructed of marine grade s/s for use in hostile environments.
  • Rugged industrial type X-Ray tube, to gives the required power continuously.

·         The 9-inch Image Intensifier and CCD Camera, together with a 12-inch high resolution TV monitor more than meets the requirements of the system.

  • A variable speed conveyor, adjustable to suit the operator’s skill, gives total flexibility.
  • Radiation leakage is well below that which is required by the authorities enabling the operator to work continuously.

 

WEIGHT

 

Approx. 210kg

 

 

 

DIMENSIONS - (incl. TV)

 

HEIGHT

 

LENGTH

 

WIDTH

Overall

1.70m

1.86m

0.82m

Lower Section

0.92m

0.90m

0.62m

Middle Section

0.21m

1.86m

0.82m

Upper Section

0.68m

1.00m

0.56m

X-RAY TUBE

Fixed anode, 65 – 85KVP @ 1mA continuous rating Air Cooled

IMAGING SYSTEM

9” Image Intensifier

CCD Miniature Camera

12” High Resolution TV Monitor

REJECTOR

Pushrod for vomit oysters

CAPACITY

1800 Oysters / Hour (dependent on oyster and operator)

CONVEYOR

490mm wide shelf, aligning vinyl belt, driven by ⅛ H.P. Variable speed geared DC motor

Bearings are ‘zero maintenance’ polymer type

POWER

Maximum power consumption is 200VA

Standard Model is 220/240/250V AC  50 or 60HZ

Other voltages to special order

DEHUMIDIFY

One 25W lamp in both upper and lower sections total power consumption 50W

ENVIRONMENTAL

  • All components in lower section sealed against salt water and deck hose
  • Upper section is completed sealed to salt water
  • Control box is splash proof only

WARRANTY

12 months back to base (Perth) parts and labour

Exceptions: 12 months back to base (Perth) parts and labour, pro-rata on xray tube and image intensifier

Excludes travel expenses to customer site if required

 

Back

Tel + 61-8-9337 7370  Fax +61-8-9337 6582 info@pearlingtechnologies.com